Type Version | -
|
Lamp Type | CDM
|
Number of Lamps | 1
piece/unit
|
Number of Products on MCB (16A Type B) (Nom) | 24
|
Automatic Restart | Yes
|
Input Voltage | 220 to 240
V
|
Input Frequency | 50 to 60
Hz
|
Minimum Mains Voltage Operation (Min) | 180
V
|
Operating Frequency (Nom) | 45-66
kHz
|
Power Factor 100% Load (Nom) | 0.95
|
Igniton Type | Pulse
|
Ignition Voltage (Max) | 5.0
kV
|
Ignition Voltage (Min) | 3.0
kV
|
Mains Voltage Performance (AC) | -8%-+6%
|
Mains Voltage Safety (AC) | 180-264V
|
Inrush Current Width | 0.25
ms
|
Constant Wattage Deviation | Not specified
|
Power Losses (Nom) | 5
W
|
Inrush Current Peak (Max) | 26
A
|
Output Voltage | -
V
|
Cable Capacity Output Wires Mutual (Nom) | 120
pF
|
Cable Length From Device to Lamp | 2
m
|
Ballast Contact Wire Cross Section | 0.75-2.50
mm²
|
Connector Type | Insert
|
Rated Ballast-Lamp Power | 35 W
|
T-Ambient (Max) | 50
°C
|
T-Ambient (Min) | -20
°C
|
T-Storage (Max) | 75
°C
|
T-Storage (Min) | -25
°C
|
T-Case Lifetime (Nom) | 75
°C
|
T-Case Maximum (Max) | 75
°C
|
Housing | /I
|
Active Temperature Protection | No
|
|||
EMI 30 MHz ... 1000 MHz | CISPR15 Edition 7.2
|
|||
Vibration Standard | IEC68-2-6 F c
|
|||
Bumps Standard | IEC 68-2-29 Eb
|
|||
Approval Marks | F-Marking
|
CE marking
|
ENEC certificate
|
VDE certificate
|
Surge Test Installation Level | EN61547
|
|||
Surge Test Performance Criterium | Not specified
|
|||
Hum And Noise Level | 37 dB(A)
|
Full product code | 871829118421800
|
Order product name | HID-PV E 35 /I CDM 220-240V
|
EAN/UPC - Product | 8718291184218
|
Order code | 913700680666
|
Numerator - Quantity Per Pack | 1
|
Numerator - Packs per outer box | 12
|
Material Nr. (12NC) | 913700680666
|
Net Weight (Piece) | 0.310
kg
|