Application Code | E+
|
Type Version | mk1
|
Lamp Type | TL5/PL-L
|
Number of Lamps | 2
piece/unit
|
Number of Products on MCB (16A Type B) (Nom) | 9
|
Automatic Restart | Yes
|
Input Voltage | 220 to 240
V
|
Input Frequency | 50 to 60
Hz
|
Operating Frequency (Max) | -
kHz
|
Operating Frequency (Min) | -
kHz
|
Ignition Method | Warm Start
|
Crestfactor (Max) | 1.7
|
Power Factor 100% Load (Nom) | 0.95
|
Ignition Time (Max) | 0.2
s
|
Mains Voltage Performance (AC) | -8%-+6%
|
Mains Voltage Safety (AC) | -10%-+10%
|
Earth Leakage Current (Max) | 0.5
mA
|
Inrush Current Width | 0.35
ms
|
Standby Power Consumption (Max) | 0.25
W
|
Ballast Factor (Nom) | 1.0
|
Power Losses (Nom) | 11.3
W
|
Inrush Current Peak (Max) | 35
A
|
Efficiency at full load [%] | 93.43
%
|
Connector Type Input Terminals | WAGO 251 universal connector
[ Suitable for both automatic wiring (ALF and ADS) and manual wiring] |
Cable Capacity Output Wires Mutual (Max) | 150
pF
|
Connector Type Output Terminals | WAGO 251 universal connector
[ Suitable for both automatic wiring (ALF and ADS) and manual wiring] |
Connector Type Control Input Terminals | WAGO 251 universal connector
[ Suitable for both automatic wiring (ALF and ADS) and manual wiring] |
Wire Striplength | 8.0-9.0
mm
|
Dual Fixture Master/Slave | -
[ not specified] |
Control Input Terminal Cross Section | 0.50-1.00
mm²
|
Input Terminal Cross Section | 0.50-1.00
mm²
|
Output Terminal Cross Section | 0.50-1.00
mm²
|
Auto Insert (ALF/ADS) Wire Cross Section | 0.5
mm²
|
Cable Capacity Output Wires to Earth (Max) | 150
pF
|
Rated Ballast-Lamp Power | 80 W
|
T-Ambient (Max) | 50
°C
|
T-Ambient (Min) | 15
°C
|
T-Storage (Range) | -40 °C to 80 °C
|
T-Storage (Max) | 80
°C
|
T-Storage (Min) | -40
°C
|
T-Case Lifetime (Max) | 75
°C
|
T-Case Maximum (Max) | 75
°C
|
Stable Lamp Operation Temperature | Not Specified
|
T-Ignition (Max) | 50
°C
|
T-Ignition (Min) | 0
°C
|
Control Interface | TD
|
Regulating Level Power | 1%-100%
|
Control Input Protection | Yes (Basic insulation)
|
Housing | L 425x30x21
|
Battery Voltage Lamp Ignition | 220
V
|
Battery Voltage Lamp Operation | 154-276
|
Energy Efficiency Index | A1
|
|||
IP Classification | IP20
[ Finger-protected] |
|||
EMI 9 kHz ... 30 MHz | EN55015
|
|||
EMI 30 MHz ... 1000 MHz | EN55022 level B
|
|||
Safety Standard | IEC 61347-2-3
|
|||
Performance Standard | IEC 60929
|
|||
Quality Standard | ISO 9000:2000
|
|||
Environmental Standard | ISO 14001
|
|||
Harmonic Current Emission Standard | IEC 61000-3-2
|
|||
EMC Immunity Standard | IEC 61547
|
|||
Vibration Standard | IEC68-2-6 F c
|
|||
Bumps Standard | IEC 68-2-29 Eb
|
|||
Humidity Standard | EN 61347-2-3 clause 11
|
|||
Approval Marks | EMC
|
CE marking
|
ENEC certificate
|
CCC certificate
|
Temperature Marking | Yes
|
|||
Emergency Standard | IEC 60598-2-22
|
|||
Hum And Noise Level | 30 dB(A)
|
Ambient temperature range | 15 °C to 50 °C
|
Full product code | 871150091067730
|
Order product name | HF-Ri TD 280 TL5/PL-L E+ 220-240V
|
EAN/UPC - Product | 8711500910677
|
Order code | 913700609666
|
Numerator - Quantity Per Pack | 1
|
Numerator - Packs per outer box | 12
|
Material Nr. (12NC) | 913700609666
|
Net Weight (Piece) | 0.417
kg
|