You are now visiting our Global professional lighting website, visit your local website by going to the USA website
  • Digital ignitors for maximum reliability

    SND 57 220-240V 50/60Hz

    SND 57 220-240V 50/60Hz

    Downloads

    Leaflet
    Size:628.4 kB

    See all downloads

Specifications Show all

General Information
Application Code
57
Lamp Type
SON
Number Of Lamps
1 piece/unit
Operating and Electrical
Input Voltage
220 to 240 V
Input Frequency
50 to 60 Hz
Igniton Type
Semi-Parallel
Ignition Attempts
3
Ignition Time (Max)
1185 s
Ignition Voltage (Max)
2.5 kV
Ignition Voltage (Min)
1.8 kV
Response Voltage
195 V
Mains Voltage Performance (AC)
-8%-+6%
Mains Voltage Safety (AC)
-10%-+10%
Power Losses (Nom)
1.0 W
Wiring
Ballast Contact Wire Cross Section
0.70-2.50 mm²
Connector Type
Screw
System characteristics
Rated Ballast-Lamp Power
50/70 W
Temperature
T-Ambient (Max)
85 °C
T-Ambient (Min)
-20 °C
T-Case Maximum (Max)
90 °C
Mechanical and Housing
Housing
SNI-85
Approval and Application
Approval Marks
CE marking
ENEC certificate
Product Data
Full product code
871150093066830
Order product name
SND 57 220-240V 50/60Hz
EAN/UPC - Product
8711500930668
Order code
913700184966
Numerator - Quantity Per Pack
1
Numerator - Packs per outer box
48
Material Nr. (12NC)
913700184966
Net Weight (Piece)
0.050 kg
Installation Diagrams
SND 57 URBIS
SND 57 URBIS

Recently Viewed

Downloads
Leaflets
Visuals

Contact us

 