OccuSwitch Wireless - switching on savings in existing installations

OccuSwitch Wireless

OccuSwitch Wireless

  • OccuSwitch Wireless - switching on savings in existing installations

    • Energy savings of up to 30%. Additional savings can be obtained in combination with ActiLume Wireless.
    • Offers an easy-to-apply solution, especially for existing non-electronic (EM) lighting systems.
    • Wireless sensor can be mounted in various places and offers maximum flexibility. The actuator is designed for any wiring system.

Videos

[trigger to render Video Gallery]

Images

Product family information

The OccuSwitch Wireless family consists of wireless sensors and an actuator (relay-box). Savings of up to 30% can be achieved by simply turning off the lights in unoccupied areas. Battery-operated, with a typical lifetime of 8-10 years. The actuator can switch any load up to 6 A and can be located in the ceiling or corridor. Designed to control an area of 20-25 m2 but the area can be expanded to 160 m2 by adding extra sensors. Up to 10 sensors and/or actuators can be combined in one parallel network. The maximum distance between the sensor and actuator is 10 meters (depending on the application).A detachable mains wiring connector enables easy installation. Separate Wieland and CEE cables are available for even easier, faster and trouble-free installation. With the extended scope of OccuSwitch Wireless functionality (increased number of sensors and interoperable with wireless ActiLume range), all wireless devices should be from the same version (LRM/LRA/LLC XXXX/10 or higher).

Features

Smart timer extends the delay time by 5% if movement is detected shortly after switch-off, assuming that the area is still in use but there is very little movement.
The ceiling sensor has a retractable shield that can be used to shield off areas, e.g. corridors adjacent to the area in which OccuSwitch Wireless is operating.
There is considerable freedom in terms of where to mount the OccuSwitch Wireless actuator to minimize installation cost and time.

Applications

Open-plan offices, schools (incl. board lighting)
Similar applications, including restrooms, corridors, storage and copy rooms, break areas, etcetera
Optimized for ceiling heights of between 2.5 and 4 meters
Installation height for corridor, corner and wall sensors between 2.1 and 2.5 meters