You are now visiting our Global professional lighting website, visit your local website by going to the USA website

Lighting in

classroom

ABT Car parking - Level 2

Step 2.1: Check the current lighting

 

Measure (in accordance with the standard EN 12464-1; 2011)

 

1.

On desk (horizontal)

  • Illuminance Em ≥ 300 Lux
  • Illuminance Em ≥ 500 lux for evening classes and adult education

 

2.

On one or two other desks (horizontal)

  • To check the light uniformity in the space.
  • Uo ≥ 0.6

 

3.

On wall, at desk height (vertical)

  • Philips recommended ≥ 75 Lux

 

4.

In between desks, on floor level

  • Philips recommended ≥ 300 Lux
Classroom diagram

Step 2.2: Check the current lighting and luminance

 

Previous      Next